理光mp5000 总是报错sc350
如题:最近有两台机器砸在手里,问题都是隔段时间就报sc350。
也参照维修手册处理,但好不了几天或者几个小时又坏。
处理过的方法: 换过高压板
换过TD传感器
换过整套套鼓
检查过TD水晶头对应插孔也是完好无损
(以上方法都试过了,都是无解。)
http://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.pnghttp://www.oachn.net/static/image/hrline/line4.png
所以请各位老师指教下到底哪里出现问题,怎么处理这个错误代码。
最重要的是,请问平常怎么操作引起报错sc350(请各位说直白点,不要太官方。例如跟下粉多少有关吗)
没有同行呀, 还是没解决。 路过,学习中 碳粉浓度太低或者太高,碳粉不好、鼓芯载体老化或者鼓芯质量有问题,导致ID传感器检测数据有偏差,经常会出现350。3103、2220、2223的数据是多少,看过吗? 通常是ID传感器脏了,清洁下 350是id,你换td意义不大吧……我遇到过这个报错,但是跟你的不太一样,一开机准报而且不会好,换高压板后修复 id传感器脏了,清洁ID传感器,如若不行就只能更换了。 楼主解决了吗?我这也是这个毛病 学习中
页: